JPHEAT editors (Kawaguchi Seiken Co., Ltd.) / Updated 2026-11-28
Before the number, ask for the conditions.
Far-infrared products often quote figures such as “far-infrared emissivity 0.9”, “over 90% emission” or “5–14 µm”. The numbers look precise, but unless you know which emissivity it is and how it was measured, you cannot compare them or tell what they describe.
This article rates no product. It explains what emissivity is, the different quantities that share the name, the usual ways to measure it, and the conditions to check when you read the data.
What emissivity is.
Anything with a temperature gives off infrared. An ideal emitter, a blackbody, gives off the theoretical maximum at every temperature and wavelength. A real material’s output as a share of a blackbody’s at the same temperature is its emissivity, a number between 0 and 1.
• Emissivity 1: the same as a blackbody. • Emissivity 0.9: at the same temperature, about 90% of a blackbody’s output. • Emissivity near 0: almost nothing given off, as with highly polished metal.
One further relation matters (Kirchhoff’s law): in thermal equilibrium, a surface’s emissivity at a given wavelength equals its absorptivity at that wavelength. A surface that readily absorbs a band of infrared also readily gives it off.
“Emissivity” is several different quantities.
• Spectral emissivity: emissivity worked out wavelength by wavelength, drawn as a curve.
• Total emissivity: one figure for all wavelengths together, weighted by the blackbody distribution at that temperature.
• Normal: counting what leaves the surface perpendicular to it. • Hemispherical: counting what leaves the surface in every direction.
So “normal total emissivity 0.89” and “emissivity 0.95 in a certain band” are different quantities and cannot be ranked against each other. The same material can also give different values at different temperatures or over different wavelength ranges.
How it is usually measured.
• Against a blackbody: the sample is heated to a set temperature, an infrared spectrometer (for example an FTIR, a Fourier-transform infrared spectrometer) records the spectrum it gives off, and that is compared with a blackbody reference at the same temperature. The result is the spectral and total emissivity.
• From reflectance: for an opaque sample, Kirchhoff’s law makes emissivity roughly 1 minus reflectance, so measuring reflectance gives emissivity.
• Quick surface methods: ASTM E408, for example, sets out methods for measuring total normal emittance with an inspection meter [1], and ASTM E1933 covers measuring and compensating for emissivity with thermal imagers [2].
Countries and fields have their own standards too. China’s national standard GB/T 7287-2008, for instance, sets methods for normal total emissivity and the relative spectrum. Different methods and sample temperatures can give values that are not directly comparable.
Five things to check in a spec.
1. Which emissivity: spectral or total? normal or hemispherical?
2. Wavelength range: measured from how many µm to how many? “5–14 µm” is a range, not an emissivity.
3. Sample and temperature: a raw material, a fabric swatch or the finished product? At what temperature?
4. Method: which standard or method?
5. Who measured it, and is there a report: the laboratory, report number and date.
A figure like “over 90% far infrared” without these conditions cannot be compared with anything. And emissivity describes how readily a surface gives off infrared; on its own it says nothing about any action on the human body.
A worked example.
Here is how the five checks map onto one set of test data that JPHEAT publishes:
• Sample: one test sample of the JPT100J single pad.
• Laboratory and report: a third-party testing laboratory in Wuhan, report (2026) WT-HWGD-01049 (the laboratory’s full name is on the technology page).
• Method: GB/T 7287-2008 (normal total emissivity: Article 18, Method B; relative spectrum: Article 20).
• Spectrum: measured 2026-09-17 at 20.0 °C, 40% RH (as stated in the report), 2.50–25.00 µm at 0.05 µm intervals.
• Results: normal total emissivity 0.89; among the recorded points, relative intensity was highest at about 8.35 µm.
Both figures are results for the JPT100J test sample under those conditions. They do not apply to other models or to every setting, and they describe how the surface gives off infrared, not any action on the human body.
In short.
• Emissivity is a ratio against a blackbody at the same temperature, between 0 and 1.
• Spectral and total, normal and hemispherical are different quantities and cannot be ranked directly.
• Common methods: comparison with a blackbody, calculation from reflectance, and methods set by standards such as ASTM.
• Check: which emissivity, the wavelength range, the sample and temperature, the method, and the lab and report.
• Emissivity describes a physical property of a surface; it does not mean any action on the human body.
Questions and answers
Is “emissivity” the same as “emittance”?
In everyday use, yes. Some standards (such as ASTM E408) say emittance for a measured surface; the idea is the same ratio against a blackbody.
Is a higher emissivity better?
Emissivity describes how readily a surface gives off infrared. Whether a value suits a use depends on the use, and different kinds of emissivity cannot be compared directly.
Is “5–14 µm” an emissivity?
No. It is a wavelength range. You still need to know which emissivity was measured over it, its value, and the conditions.
Why do sellers quote different values for the same kind of material?
The sample form (raw material, swatch or finished product), temperature, wavelength range and method all change the value. Figures without conditions cannot be compared.
Why do thermal cameras need an emissivity setting?
A thermal camera works out temperature from the infrared it receives. Surfaces with different emissivities give off different amounts at the same temperature, so the camera corrects for emissivity to get close to the real surface temperature.
Sources
- [1] ASTM E408, Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques ↗
- [2] ASTM E1933, Standard Practice for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers ↗
- [3] CIE vocabulary: infrared and the IR-A / IR-B / IR-C bands ↗
- [4] A&D technical note: how infrared thermometers work (PDF, Japanese) ↗
- [5] BOKEN Quality Evaluation Institute: evaluating far-infrared emitting materials (Japanese) ↗
The public sources explain general physical principles and terms; they do not mean that these institutions recommend JPHEAT products, and they say nothing about any action on the human body.